How to specify a wire harness: a drawing checklist that avoids three rounds of questions
The ten things every harness drawing should state, what happens when each one is missing, and a short template you can send instead of a drawing.
Most harness quotations come back late because the drawing was not complete enough to quote. Not because the factory is slow — because every missing dimension becomes an email, and every email waits for a time zone.
This is the checklist we work through on every enquiry. Ten items, in the order they matter.
The ten items
1. Connector part numbers, at both ends
Not “XT60 style”. The exact body: XT60-M, XT60-F, XT60H-F, LCB30-F. Where a connector is specified by the customer, the part number settles contact size, plating and housing.
If missing: we guess, and guess wrong about gender or variant.
2. Wire gauge and insulation
12 AWG silicone is a specification; 12 AWG alone is not — PVC and silicone have very
different temperature limits and flexibility.
If missing: we default to PVC, which may fail in a hot enclosure.
3. Cut length, with a measurement datum
Length between which two points? Connector tip to connector tip, or stripped end to stripped end? A 20 mm difference in datum is a rejected batch.
If missing: the first article is measured wrong.
4. Strip and tin length
How much insulation comes off, and whether the exposed strands are tinned.
If missing: strip length is decided at the machine, and may not suit your terminal block or solder cup.
5. Branch layout for multi-leg harnesses
Where each branch leaves the main run, at what distance, and in which direction.
If missing: the harness fits but does not route.
6. Sleeving, tape and protection
Heat-shrink at the ends? Braided sleeve over the whole run? Spiral wrap? Conduit? Each adds cost and diameter.
If missing: quoted without protection, then re-quoted.
7. Labeling
Part number, batch number, cell number, or customer label artwork. State the format and position.
If missing: arrives unlabelled, and cannot be matched to the work order in the field.
8. Electrical test requirement
Continuity only, or continuity plus hipot? At what voltage for how long? Contact resistance measurement?
If missing: we test to our default, which may not satisfy your incoming inspection.
9. Quantity and annual volume
The first order quantity and the expected annual volume. Tooling decisions and unit price both depend on it.
If missing: quoted at prototype pricing for a production quantity.
10. Destination and shipping term
EXW, FOB, or DDP — and the destination country, because it affects both freight and the documentation set.
If missing: the quote excludes freight you expected to be included.
A template you can send instead
If you do not have a drawing, this is enough to start:
Part: [your reference]
Connector A: [exact body, e.g. XT60-F]
Connector B: [exact body, e.g. EC5]
Wire: [gauge + insulation, e.g. 12 AWG silicone]
Length: [value + datum, e.g. 300 mm tip-to-tip]
Strip / tin: [e.g. 8 mm strip, 3 mm tin]
Sleeving: [e.g. 40 mm heat-shrink each end]
Labeling: [e.g. part no. on 30 mm label, 100 mm from A end]
Test: [e.g. 100% continuity, hipot 500 V AC 1 min]
Quantity: [first order + annual]
Destination: [country + Incoterm]
That is a complete enquiry. It usually produces a quotation in one round.
What a photograph can and cannot replace
A photograph with a ruler in frame is genuinely useful for a sample-matching job — we can reverse-engineer a part you already have. It is not sufficient for a production order, because the drawing is what gets inspected against.
For sample matching, send:
- The sample itself, or clear photos from three angles
- A ruler or caliper in frame
- The connector part numbers if legible
- The quantity you expect
We will return a drawing for your approval before production runs.
Frequently asked
Can you work from a competitor’s part number? Yes, if it is a standard catalog part we can usually match it. Where it is a custom assembly, we need the drawing or the sample.
What is the minimum information you can quote from? Connectors, gauge, length and quantity. Everything else improves the quote but is not a blocker.
How long does a quotation take? One working day for a standard assembly. Longer if a connector has to be sourced specifically.
Send the checklist above, or a drawing, and we will quote within one working day and sign an NDA before drawings change hands.
Need this built to your drawing?
Send the drawing, the gauge and the annual volume — we quote within one working day and sign an NDA before drawings change hands.