Knowledge base
Notes for people who have to specify the part
25 technical notes on connector ratings, wire gauge, crimp quality and sourcing — written for buyers and design engineers, and tied to the assemblies we actually build.
Selection guides
8- Selection guides The number is not the rating: XT, EC, MR and MT model numbers decoded An XT60 is not a 60 A connector, and an MR30 is not 30 A. What the numbers in these connector names actually mean, with the real current ratings behind each one.
- Selection guides XT60 vs XT90 vs XT150: choosing by continuous current, not by name A practical comparison of the three XT body sizes — contact area, real continuous rating, typical wire gauge and where each one is the wrong choice.
- Selection guides Wire gauge and current: an AWG to mm² ampacity table for harness design How AWG, mm² and ampacity line up, why the same 12 AWG lead can be rated 20 A or 35 A depending on the connector, and how to pick a gauge without over-specifying.
- Selection guides MC4, Anderson and SAE: choosing a connector for solar and 12 V circuits Three connectors dominate low-voltage solar and RV wiring. What each one is actually rated for, where the ratings are misread, and how to bridge between them.
- Selection guides XT60 vs XT60H: the latch is worth more than the current rating The XT60H is rated lower than a plain XT60 — 25 A against 35 A — yet it is the right choice on vehicles and machinery. Here is why, and when it is not.
- Selection guides Anderson 30 A vs 50 A: housing sizes, contact area and when to step up The two Anderson housings look similar and do not interchange. How to tell them apart, what each is rated for, and the point at which 30 A stops being enough.
- Selection guides LCB30 vs LCB40 vs LCB50: choosing a latched two-pin connector Three sizes of the same latched body. What the datasheet actually confirms for LCB30, what we will not claim for LCB40 and LCB50, and how to decide between them.
- Selection guides How to specify a wire harness: a drawing checklist that avoids three rounds of questions The ten things every harness drawing should state, what happens when each one is missing, and a short template you can send instead of a drawing.
Technical notes
7- Technical notes Contact resistance matters more than the current rating on the box Why a 2 mΩ joint at 30 A dissipates nearly 2 W in a space the size of a fingernail, and what mΩ figures on a datasheet actually measure.
- Technical notes Crimp quality: height, pull force and what to look for A crimp that passes a visual check can still fail a pull test. What crimp height and pull force actually measure, and the three defects that reach the customer most often.
- Technical notes IP ratings on cable assemblies: what IP40 and IP67 actually promise The two digits mean different things, and the rating belongs to the whole assembly — not to the connector alone. Where IP67 assemblies fail and why.
- Technical notes Silicone vs PVC vs XLPE: choosing insulation for a harness Conductor gauge gets the attention, insulation decides whether the assembly survives. Temperature limits, flexibility and where each material is the wrong choice.
- Technical notes What a 100% continuity test actually catches — and what it misses Continuity testing is the standard final gate on every harness. It finds wrong pins and open circuits. It does not find a high-resistance crimp, and that is the one that returns.
- Technical notes Overmolding vs heat-shrink: which strain relief survives Both protect the cable exit; they fail differently. Where a molded boot is worth the tooling cost, and where a heat-shrink boot is genuinely enough.
- Technical notes UL94 V-0, GWFI and glow-wire: what flammability ratings cover A connector rated UL94 V-0 is not fireproof, and the rating applies to a test specimen at a specified wall thickness. How to read the three ratings that appear on connector datasheets.
Application notes
6- Application notes Wiring a camper van solar system: panel to battery, connector by connector A practical walk through a 12 V camper solar install — which connector at each junction, what each is rated for, and the three places the wiring usually goes wrong.
- Application notes Battery swap cabinets: choosing a connector for thousands of cycles A swap cabinet connector is handled hundreds of times a day by gloved hands. What that does to cycle life, plating and connector design — and why a standard XT is the wrong part.
- Application notes BMS sensing harnesses: cell count, sequence and the mistakes that cost a pack A BMS harness carries one lead per cell group. Wrong length or wrong sequence misreports voltages — and on a lithium pack that can mean a destroyed module.
- Application notes Energy storage cabinet DC wiring: lugs, torque and the inspection that matters Residential storage cabinets connect with bolted lugs, not connectors. Crimp quality, lug bore, torque and the two inspection points that predict a failure years later.
- Application notes Servo motor cables: keep power and encoder separate or fight noise forever A motion axis carries PWM power and microvolt encoder signals in the same bundle. Why combining them into one jacket causes problems that look like everything except a wiring fault.
- Application notes M8, M12 or M16: choosing a waterproof sensor connection Three thread sizes cover industrial sensor wiring. What each is used for, how coding prevents expensive misconnections, and why IP67 alone does not make a washdown connection.
Standards & sourcing
4- Standards & sourcing IATF 16949 vs ISO 9001: what the certificates actually cover A supplier claiming both is not necessarily twice as good — but the difference matters. What each standard covers, what it does not guarantee, and which questions to ask before you rely on it.
- Standards & sourcing RoHS and REACH for cable assemblies: what to ask a supplier for A "RoHS compliant" line on a datasheet is not a declaration. What the two regulations actually require of a harness, and the paperwork that satisfies a European customer.
- Standards & sourcing MOQ, tooling and sample lead time: how a harness quotation is actually structured Why one supplier quotes 500 pcs minimum and another 5,000, where tooling charges come from, and the four numbers in a quote that determine whether the price is real.
- Standards & sourcing How to audit a wire harness factory remotely You cannot fly to Dongguan for every supplier. The eight things that can be verified from photographs, documents and a video call — and the three that genuinely need a visit.
Question not covered here?
Send it with the drawing and we will answer it with your part in front of us.