JIANA ZHILIAN Wire Harness · Dongguan, China
Technical notes

UL94 V-0, GWFI and glow-wire: what flammability ratings cover

A connector rated UL94 V-0 is not fireproof, and the rating applies to a test specimen at a specified wall thickness. How to read the three ratings that appear on connector datasheets.

5 min read

Connector datasheets carry three different flammability numbers, and they are often quoted interchangeably in marketing. They test different things.

UL94 V-0

UL94 tests how a plastic specimen behaves when a flame is applied and then removed. The rating describes self-extinguishing behavior, not fire resistance.

Rating After-flame time Dripping
V-0 ≤ 10 s per specimen No burning drips
V-1 ≤ 30 s No burning drips
V-2 ≤ 30 s Burning drips permitted

V-0 is the strictest of the vertical burn ratings and the one most commonly specified. It means: remove the flame, and the material stops burning within ten seconds without dripping flaming material.

What it does not mean: the part will not ignite, will not melt, or will survive a fire. It means the plastic does not sustain combustion on its own.

The wall-thickness caveat

UL94 ratings are thickness-dependent. A datasheet reading UL94 V-0 (0.8 mm) applies to a specimen 0.8 mm thick. A thicker section of the same material may rate differently — usually better, but not automatically.

This is why our LCB30 page states UL94 V-0 (0.8 mm wall) rather than just “V-0”. The qualifier is part of the claim.

GWFI (glow-wire flammability index)

GWFI is a different test: a heated glow-wire is applied at a defined temperature, and the material must extinguish within 30 seconds without igniting a tissue-paper layer beneath.

GWFI 850 °C means the material passed at 850 °C. It is common in appliance and connector specifications where the risk is a glowing element rather than an open flame.

GWFI and UL94 are not comparable — a material can pass one and fail the other.

Glow-wire ignition (GWFI vs GWIT)

Two related figures appear:

  • GWFI — glow-wire flammability index: the temperature at which the material does not sustain burning
  • GWIT — glow-wire ignition temperature: the temperature at which it does not ignite at all

GWIT is always lower than GWFI, because igniting is easier than sustaining.

What matters for a connector

For a battery or charging application, the relevant question is not “is the plastic V-0” but “what happens if a contact overheats”.

V-0 housing material buys you time: the plastic does not propagate a flame. It does not prevent the contact from overheating in the first place — that is a function of contact resistance and current density.

Practical specification:

Application Sensible requirement
Consumer electronics internal UL94 V-0
Battery and charging UL94 V-0 + GWFI 850 °C
Appliance near heating elements UL94 V-0 + GWFI/GWIT per IEC 60335
Automotive under-bonnet UL94 V-0, material per OEM spec

Frequently asked

Is V-0 better than V-2 in practice? For a connector, yes — V-2 permits burning drips, and a burning drip inside an enclosure is worse than a self-extinguishing part.

Does a V-0 connector make the assembly fire-safe? No. The housing is one component. The wire insulation, the sleeving and the surrounding materials all contribute, and a V-0 connector on PVC wire does not make a fire-rated assembly.

Why do some datasheets say “V-0 equivalent”? Because the material was tested to another standard (IEC 60695, for example) and the supplier is indicating approximate equivalence. Treat it as unverified unless the test report says otherwise.


If your application requires documented flammability performance, tell us the standard and we will confirm which housing material meets it rather than quoting a rating label.

Need this built to your drawing?

Send the drawing, the gauge and the annual volume — we quote within one working day and sign an NDA before drawings change hands.

Request a quotation