JIANA ZHILIAN Wire Harness · Dongguan, China
Technical notes

Crimp quality: height, pull force and what to look for

A crimp that passes a visual check can still fail a pull test. What crimp height and pull force actually measure, and the three defects that reach the customer most often.

6 min read

Crimping is the most common termination in harness manufacturing and the most common source of field failures. Unlike soldering, the joint is invisible after the insulation and boot go on — so quality has to be controlled by measurement during the process, not by inspection at the end.

The two measurements

Crimp height is the thickness of the crimped barrel, measured with a micrometer. Too high means the barrel was not compressed enough — the strands are loose and resistance is high. Too low means over-compression — strands are cut or the barrel is weakened.

Every terminal has a specified height window, typically a 0.05 mm band. It is measured on a sample from each batch.

Pull force is the tensile load at which the crimped joint separates, measured on a tension meter. It catches things crimp height alone cannot: wrong terminal, wrong strand count, damaged wire.

Measurement Catches Misses
Crimp height Over/under compression, tooling drift Strand damage, wrong wire
Pull force Insufficient grip, wire and terminal mismatch A joint that grips but conducts badly

You need both. Height alone can be correct on a joint that pulls apart at 30 N because the wire was nicked during stripping.

The three defects that reach the customer

1. Strands cut during stripping

A stripping blade set too deep nicks strands. Crimp height and pull force both pass, because the remaining strands are properly crimped — until vibration breaks the nicked ones and resistance climbs. The visual tell is a shorter, ragged conductor in the barrel.

2. Insulation inside the barrel

If strip length exceeds the barrel, insulation enters the crimp. It cushions the compression, so crimp height reads correct while the actual metal-to-metal contact is poor. The tell is insulation visible in the wire-crimp transition.

3. Bell-mouth missing or excessive

A correct crimp has a small bell-mouth at the conductor and insulation ends — the barrel is not compressed to the very edge. A missing bell-mouth means the tooling is over-set and stress-rises at the edge; an excessive one means under-fill.

What we do about it

  • Crimp height measured on a sample per batch, recorded against the work order
  • Pull force tested on a tension meter at the same time
  • In-line crimp-force monitoring on semi-automatic presses, which catches drift between samples
  • 100% continuity test on the finished assembly, plus 100% visual on the crimp zone

The records are filed by batch, so a claim can be traced to the sample taken from that batch.

What you should ask a supplier

  1. Do you measure crimp height and pull force, and can I see the records?
  2. What are the acceptance windows for my terminal, and what standard are they from?
  3. How often is a sample taken — per batch, per shift, or per work order?
  4. Is there in-line force monitoring, or only sampled measurement?

A supplier who cannot answer these is crimping to feel, not to specification.

Frequently asked

Is soldering better than crimping? No, for stranded wire in a vibrating environment. Solder wicks up the strands and creates a stiff-to-flexible transition where fatigue failures start. Crimping is the correct termination for most harness work.

My crimp passes pull force but the joint gets hot. Why? Check the wire-to-terminal size match first, then the strand condition. A joint can grip well with fewer strands than specified, and current capacity scales with strand cross-section.

Can I verify a crimp without a tension meter? Not reliably. Visual inspection catches gross defects but not marginal grip. If you do volume work, a pull tester is not optional.


We measure and record crimp height and pull force on every batch. If your incoming inspection needs a specific format, tell us and we will supply the records in that form.

Need this built to your drawing?

Send the drawing, the gauge and the annual volume — we quote within one working day and sign an NDA before drawings change hands.

Request a quotation

← All technical notes