Servo motor cables: keep power and encoder separate or fight noise forever
A motion axis carries PWM power and microvolt encoder signals in the same bundle. Why combining them into one jacket causes problems that look like everything except a wiring fault.
A servo axis has two electrical environments in the same physical space: a PWM power conductor switching hundreds of volts at kilohertz, and an encoder pair carrying millivolt differential signals. Put them in one jacket without separation and the encoder will pick up the switching edges.
The symptoms do not look like a wiring problem. They look like:
- Position jitter that appears at certain speeds
- A drive that faults on encoder error intermittently
- Following error that grows with acceleration
- Random missed counts that repeat at the same point in the cycle
Why separation matters
A motor power conductor switching 400 V in under a microsecond couples capacitively and inductively into anything running parallel to it. The encoder signal is differential and small — tens of millivolts — so a coupled volt is a total loss of signal integrity.
Cable construction addresses this in three ways:
| Technique | What it does |
|---|---|
| Shielded power conductors | Contains the switching field inside the power pair |
| Shielded, twisted encoder pairs | Rejects common-mode noise; twisting makes the loop area small |
| Physical separation in the jacket | Reduces capacitive coupling between groups |
All three together is what a proper motion cable provides. A “servo cable” made from generic shielded cable usually has only one.
What separates a motion cable from a good cable
Continuous flex construction. In a cable track, the conductors must be stranded for flexing — finer strands, shorter lay length, and often a filler to keep the geometry stable. A standard cable in a track fails at the conductor level within a few hundred thousand cycles.
Bend radius. Every motion cable has a minimum dynamic bend radius, typically 7.5–10× the cable diameter. Violating it is the most common cause of premature failure — more common than electrical problems.
Jacket material. PUR for abrasion and oil resistance in a track. PVC work-hardens and cracks.
Wiring practice that avoids the rest of the problems
Ground the shield at both ends for high-frequency noise, or at the drive end only if you have a specific reason. A shield grounded at one end only is an antenna at high frequency.
Route power and encoder in separate ducts where the cabinet layout allows, and cross at right angles rather than running parallel.
Keep the encoder cable’s shield continuous through any junction — a break in the shield is worse than no shield, because it becomes a slot antenna.
Do not share a connector between power and encoder unless the connector is designed for it, with separate shielded cavities.
Specifying a motion cable
Axis type: Servo, 400 V, 5 A continuous
Power conductors: 4 × 1.5 mm², shielded
Encoder: 2 pairs shielded twisted + 2 power for encoder supply
Flex: Continuous, cable track, 5 M cycles
Bend radius: 7.5 × OD dynamic
Jacket: PUR, oil resistant
Connectors: Drive-end and motor-end per drive model
That is enough to quote and to build. Anything less and the cable becomes a compromise.
Frequently asked
Can I use one cable for a small servo? Some integrated servo systems do combine power and feedback in one cable, using a connector designed for it with segregated cavities and individual shields. A generic combined cable is not the same thing.
Is a shielded cable enough? Shielding helps, but a shielded combined cable with power and encoder adjacent still couples. Separation inside the jacket matters as much as the outer shield.
How do I know if noise is the problem? Scope the encoder lines while the motor runs. Switching noise appears synchronised with the PWM frequency, which is diagnostic.
If a new axis is faulting intermittently, send us the drive model, the motor cable length and the track layout, and we will specify a cable construction for it.
Need this built to your drawing?