JIANA ZHILIAN Wire Harness · Dongguan, China
Technical notes

IP ratings on cable assemblies: what IP40 and IP67 actually promise

The two digits mean different things, and the rating belongs to the whole assembly — not to the connector alone. Where IP67 assemblies fail and why.

5 min read

An IP rating has two digits and they are independent. Reading “IP67” as a single unit leads people to assume protection properties the part does not have.

What the digits mean

First digit — solids (0–6).

  • 4 = protected against objects larger than 1 mm (tool, wire)
  • 5 = dust-protected (limited ingress, no harmful deposit)
  • 6 = dust-tight (no ingress)

Second digit — liquids (0–8).

  • 0 = no protection
  • 4 = splashing water from any direction
  • 7 = immersion to 1 m for 30 minutes
  • 8 = continuous immersion, depth specified by the manufacturer

So IP40 means 1 mm solid protection and no liquid protection at all. That is the rating on a standard molded XT60 lead — fine on a bench, not fine in a wet engine bay.

IP67 means dust-tight and immersible to 1 m for 30 minutes. That is the rating on a properly sealed charging inlet.

The rating belongs to the assembly, not the connector

This is where most specification goes wrong. An IP67 connector body mated with a non-sealed counterpart, or terminated onto a cable whose jacket is not sealed to the housing, is not an IP67 assembly.

The weak points, in order:

  1. The cable exit. A molded or overmolded exit seals; a heat-shrink boot may not.
  2. The mating interface. Only sealed when mated with a matching part, and only with the gasket intact.
  3. The far end. An IP67 connector on one end and an open termination on the other gives you nothing.
  4. The jacket. A cable with a wicking construction can draw water along the strands even with a sealed entry.

A supplier claiming “IP67 connector” has told you about one component. Ask what the assembly is rated at, and how it was tested.

Where IP67 assemblies still fail in service

  • Unmated and left open. The rating applies mated; an open connector collects water.
  • Gasket compression lost. Repeated mating wears or deforms the seal.
  • Cable flexed at the entry. Strain relief protects the seal — without it, the jacket works loose and the seal is bypassed.
  • Thermal cycling. Expansion and contraction at the seal can open a path that a static immersion test does not find.

Choosing a rating

Environment Minimum sensible rating
Control cabinet interior IP40 or none
Vehicle interior IP40–IP54
Engine bay, underbody IP67
Washdown equipment IP67 (IP69K for high-pressure jets)
Outdoor cabinet IP65+ at the entry
Immersible equipment IP67 or IP68

Do not over-specify. An IP68 assembly costs materially more than IP67, and if the equipment never sees immersion, that cost is wasted.

Frequently asked

Is IP67 the same as waterproof? No. “Waterproof” is not a defined term. IP67 defines a specific immersion depth and duration; beyond that, the part is untested.

Can I test IP rating myself? Immersion testing is straightforward for IP67; dust testing is not. For a supplier claim, ask for the test report, not the catalog number.

Does the rating survive repeated mating? The standard tests a new part. After many cycles the gasket degrades — cycle life and IP rating should be read together.


If your application involves washdown, immersion or an outdoor cabinet, tell us where the connection sits and we will specify a sealed assembly and state exactly what it is rated to.

Need this built to your drawing?

Send the drawing, the gauge and the annual volume — we quote within one working day and sign an NDA before drawings change hands.

Request a quotation

← All technical notes