IP ratings on cable assemblies: what IP40 and IP67 actually promise
The two digits mean different things, and the rating belongs to the whole assembly — not to the connector alone. Where IP67 assemblies fail and why.
An IP rating has two digits and they are independent. Reading “IP67” as a single unit leads people to assume protection properties the part does not have.
What the digits mean
First digit — solids (0–6).
4= protected against objects larger than 1 mm (tool, wire)5= dust-protected (limited ingress, no harmful deposit)6= dust-tight (no ingress)
Second digit — liquids (0–8).
0= no protection4= splashing water from any direction7= immersion to 1 m for 30 minutes8= continuous immersion, depth specified by the manufacturer
So IP40 means 1 mm solid protection and no liquid protection at all. That is the rating on a standard molded XT60 lead — fine on a bench, not fine in a wet engine bay.
IP67 means dust-tight and immersible to 1 m for 30 minutes. That is the rating on a properly sealed charging inlet.
The rating belongs to the assembly, not the connector
This is where most specification goes wrong. An IP67 connector body mated with a non-sealed counterpart, or terminated onto a cable whose jacket is not sealed to the housing, is not an IP67 assembly.
The weak points, in order:
- The cable exit. A molded or overmolded exit seals; a heat-shrink boot may not.
- The mating interface. Only sealed when mated with a matching part, and only with the gasket intact.
- The far end. An IP67 connector on one end and an open termination on the other gives you nothing.
- The jacket. A cable with a wicking construction can draw water along the strands even with a sealed entry.
A supplier claiming “IP67 connector” has told you about one component. Ask what the assembly is rated at, and how it was tested.
Where IP67 assemblies still fail in service
- Unmated and left open. The rating applies mated; an open connector collects water.
- Gasket compression lost. Repeated mating wears or deforms the seal.
- Cable flexed at the entry. Strain relief protects the seal — without it, the jacket works loose and the seal is bypassed.
- Thermal cycling. Expansion and contraction at the seal can open a path that a static immersion test does not find.
Choosing a rating
| Environment | Minimum sensible rating |
|---|---|
| Control cabinet interior | IP40 or none |
| Vehicle interior | IP40–IP54 |
| Engine bay, underbody | IP67 |
| Washdown equipment | IP67 (IP69K for high-pressure jets) |
| Outdoor cabinet | IP65+ at the entry |
| Immersible equipment | IP67 or IP68 |
Do not over-specify. An IP68 assembly costs materially more than IP67, and if the equipment never sees immersion, that cost is wasted.
Frequently asked
Is IP67 the same as waterproof? No. “Waterproof” is not a defined term. IP67 defines a specific immersion depth and duration; beyond that, the part is untested.
Can I test IP rating myself? Immersion testing is straightforward for IP67; dust testing is not. For a supplier claim, ask for the test report, not the catalog number.
Does the rating survive repeated mating? The standard tests a new part. After many cycles the gasket degrades — cycle life and IP rating should be read together.
If your application involves washdown, immersion or an outdoor cabinet, tell us where the connection sits and we will specify a sealed assembly and state exactly what it is rated to.
Need this built to your drawing?
Send the drawing, the gauge and the annual volume — we quote within one working day and sign an NDA before drawings change hands.